Journal Information
Vol. 14. Issue 4.
Pages 487-507 (July - August 2008)
Share
Share
Download PDF
More article options
Vol. 14. Issue 4.
Pages 487-507 (July - August 2008)
Artigo Original/Original Article
Open Access
Qualidade do ar interior e sintomas respiratórios em escolas do Porto
Indoor air quality and respiratory symptoms in Porto schools
Visits
4525
Sílvia Fraga1, Elisabete Ramos1, Anabela Martins2, Maria João Samúdio2, Gabriela Silva2, Joaquim Guedes3, Eduardo Oliveira Fernandes2, Henrique Barros1
1 Serviço de Higiene e Epidemiologia da Faculdade de Medicina da Universidade do Porto / Hygiene and Epidemiology Unit, School of Medicine, Universidade do Porto
2 Instituto de Engenharia Mecânica da Faculdade de Engenharia da Universidade do Porto / Mechanical Engineering Institute, School of Engineering, Universidade do Porto
3 Faculdade de Ciências da Universidade do Porto / Faculty of Science, Universidade do Porto
This item has received

Under a Creative Commons license
Article information
Resumo

Objectivo: Avaliar a associação entre a qualidade do ar interior em escolas da cidade do Porto e a prevalência de patologia alérgica e respiratória nos adolescentes que as frequentam.

Participantes e métodos: Foi avaliada temperatura, humidade relativa, concentração de CO2 (dióxido de carbono) e de COV (compostos orgânicos voláteis) em nove escolas públicas da cidade do Porto. Em cada escola foram avaliados os alunos de nove turmas do 7.º, 8.º e 9.º anos, num total de 1607 adolescentes com média de idades de 14,0 (desvio-padrão=0,3) anos. A avaliação foi feita através de um questionário que compreendia questões referentes a características demográficas, sociais e comportamentais do adolescente e características da habitação de residência. Utilizou-se o questionário do International Study of Asthma and Allergies in Childhood (ISAAC) para avaliar a sintomatologia respiratória.

Resultados: Nos doze meses que antecederam a avaliação, referiram ter tido asma 5,8% dos adolescentes, pieira 9,2%, crises de espirros 22,0% e alterações na pele 6,6%.

Após ajuste para a escolaridade dos pais, valores de CO2 > 2100ppm associaram-se a pieira durante o exercício [OR=1,86 (IC95% 1,20-2,89)] e tosse nocturna [OR=1,40 (0,95-2,06)]. Observou-se um aumento da estimativa de risco de sintomas de pieira nos últimos 12 meses, asma alguma vez na vida e nos últimos 12 meses e tosse nocturna nas escolas com valores mais elevados de COV, embora a associação não seja estatisticamente significativa.

Conclusão: Piores indicadores de qualidade do ar interior, nomeadamente concentração de CO2, associaram-se a maior sintomatologia respiratória.

Rev Port Pneumol 2008; XIV (4): 487-507

Palavras-chave:
Sintomas respiratórios
escolas
adolescentes
Abstract

Aim: To evaluate the association between the indoor air quality in Porto schools and the prevalence of allergic and respiratory symptoms in adolescents.

Material and methods: Temperature, relative humidity, carbon dioxide (CO2) and volatile organic compound (VOC) concentrations were evaluated in nine Porto schools. Questionnaires were distributed to 9 classes of 7th, 8th and 9th year students in each school, total 1607 adolescents, with a mean age of 14.0years (standard deviation=0.3). Information was collected on participants’ socio-demo-graphic and social characteristics, behaviour, and housing conditions. The International Study of Asthma and Allergies in Childhood (ISAAC) questionnaire was used to evaluate respiratory symptoms.

Results: 5.8% of participants stated they had had asthma, 9.2% wheezing, 22.0% sneezing and 6.6% itchy rash In the 12 months preceding the evaluation.

After adjustment for parental educational attainment level, CO2 > 2100ppm values were associated with exercise-induced wheeze [OR=1.86 (95%CI:1.20-2.89)] and night cough [OR=1.40 (4.20-2.89)]. We observed an increasing odds ratio in wheezing symptoms over the last 12 months, in asthma ‘at some point’ and asthma over the last 12 months, and night cough at schools with higher VOC values. The association was not statistically significant, however.

Conclusion: Lower indicators of indoor air quality, particularly CO2, were associated with a greater respiratory symptomatology.

Rev Port Pneumol 2008; XIV (4): 487-507

Key-words:
Respiratory symptoms
schools
adolescents
Full text is only aviable in PDF
Bibliografia / Bibliography
[1.]
Prevention of Allergy and Allergic Asthma, WHO, (2003),
[2.]
S.A. Moonie, D.A. Sterling, L. Figgs, M. Castro.
Asthma status and severity affects missed school days.
J Sch Health, 76 (2006), pp. 18-24
[3.]
J.M. Daisey, W.J. Angell, M.G. Apte.
Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information.
Indoor Air, 13 (2003), pp. 53-64
[4.]
P. Blondeau, V. Iordache, O. Poupard, D. Genin, F. Allard.
Relationship between outdoor and indoor air quality in eight French schools.
[5.]
M.J. Mendell, G.A. Heath.
Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature.
Indoor Air, 15 (2005), pp. 27-52
[6.]
A.T. Hodgson, D.G. Shendell, W.J. Fisk, M.G. Apte.
Comparison of predicted and derived measures of volatile organic compounds inside four new relocatable classrooms.
Indoor Air, 14 (2004), pp. 135-144
[7.]
C.G. Bornehag, J. Sundell, T. Sigsgaard.
Dampness in buildings and health (DBH): Report from an ongoing epidemiological investigation on the association between indoor environmental factors and health effects among children in Sweden.
[8.]
J. Sundell.
On the history of indoor air quality and health.
[9.]
J.L. Kim, L. Elfman, Y. Mi, M. Johansson, G. Smedje, D. Norback.
Current asthma and respiratory symptoms among pupils in relation to dietary factors and allergens in the school environment.
Indoor Air, 15 (2005), pp. 170-182
[10.]
E. Ramos, H. Barros.
Family and school determinants of overweight in 13-year-old Portuguese adolescents.
Acta Paediatric, 96 (2007), pp. 281-286
[11.]
Norma ISO 16017-1:2000 Indoor, ambient and workplace air – Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/cap-illary gas chromatography – Part 1: Pumped sampling.
[12.]
ASHRAE.
Standard 55, Thermal Environmental Conditions for Human Occupancy, Atlanta, GA, American Society of Heating, Refrigeration and Air-conditioning Engineers, (2004),
[13.]
ASHRAE.
Standard 62, Ventilation for Acceptable Indoor Air Quality, Atlanta, GA, American Society of Heating, Refrigeration and Air- conditioning Engineers, (2001),
[14.]
Decreto-Lei n.º 79/2006 de 4 de Abril – Regulamento dos Sistemas Energéticos de Climatização em Edifícios (RSECE).
[15.]
B. Seifert.
Regulating indoor air.
Indoor Air ‘90’, pp. 35-49
[16.]
M.I. Asher, U. Keil, H.R. Anderson, R. Beasley, J. Crane, F. Martinez, et al.
International Study of Asthma and Allergies in Childhood (ISAAC): rationale and methods.
Eur Respir J, 8 (1995), pp. 483-491
[17.]
R.J. Kuczmarski, C.L. Ogden, S.S. Guo, L.M. Grummer-Strawn, K.M. Flegal, Z. Mei, et al.
2000 CDC Growth Charts for the United States: methods and development.
Vital Health Stat, 11 (2002), pp. 1-190
[18.]
D. Shusterman, M.A. Murphy.
Nasal hyperreactivity in allergic and non-allergic rhinitis: a potential risk factor for non-specific building-related illness.
Indoor Air, 17 (2007), pp. 328-333
[19.]
A.L. Sunesson, I. Rósen, B. Stenberg, M. Sjostrom.
Multivariate evaluation of VOCs in buildings where people with non-specific building-related symptoms perceive health problems and in buildings where they do not.
Indoor Air, 16 (2006), pp. 383-391
[20.]
J.-H. Park, P.L. Schleiff, M.D. Atttfield, J.M. Cox-Ganser, K. Kreiss.
Building-related respiratory symptoms can be predicted with semi-quantitative indices of exposure to dampness and mold.
Indoor Air, 14 (2004), pp. 425-433
[21.]
Y. Saijo, R. Kishi, F. Sata, Y. Katakura, Y. Urashima, A. Hatkeyama, et al.
Symptoms in relation to chemicals and dampness in newly built dwellings.
Int Arch Occup Environ Health, 77 (2004), pp. 461-470
[22.]
J. Pinto, M. Almeida.
A Criança Asmática no Mundo da Alergia: Euromédice, (2003),
[23.]
A.A. Arif, S.M. Shah.
Association between personal exposure to volatile organic compounds and asthma among US adult population.
Int Arch Occup Environ Health, 80 (2007), pp. 711-719
[24.]
D. Norback, E. Bjornsson, C. Janson, J. Widstrom, G. Boman.
Asthmatic symptoms and volatile organic compounds, formaldehyde, and carbon dioxide in dwellings.
Occup Environ Med, 52 (1995), pp. 388-395
[25.]
K. Rumchev, J. Spickett, M. Bulsara, M. Phillips, S. Stick.
Association of domestica exposure to volatile organic compounds with asthma in young children.
Thorax, 59 (2004), pp. 746-751
[26.]
G.D. Smith, C. Hart, C. Hole, P. Mackinnon, C. Gillis, G. Watt, et al.
Education and occupational social class: which is the more important indicator of mortality risk?.
J Epidemiol Community Health, 52 (1998), pp. 153-160
[27.]
T.A. Eikemo, M. Huisman, C. Bambra, A.E. Kunst.
Health inequalities according to educational level in different welfare regimes: a comparison of 23 European countries.
Sociol Health Illn, (2008),
[28.]
B.C. Armstrong, E. White, R. Saracci.
Principles of exposure measurement in Epidemiology.
Oxford University Press, (1994),
Copyright © 2008. Sociedade Portuguesa de Pneumologia/SPP
Pulmonology
Article options
Tools

Are you a health professional able to prescribe or dispense drugs?