Journal Information
Vol. 26. Issue 5.
Pages 327-329 (September - October 2020)
Share
Share
Download PDF
More article options
Visits
4798
Vol. 26. Issue 5.
Pages 327-329 (September - October 2020)
Letter to the Editor
Open Access
Strengths of breath-triggered inhalers in asthma management
Visits
4798
M. Morais-Almeidaa,1,
Corresponding author
mmoraisalmeida@netcabo.pt

Corresponding author.
, H. Pitéb,c,1, J. Cardosod,e, R. Costaf,g, C. Robalo Cordeiroh,i, E. Silvaj,k, A. Todo-Boml,i, C. Vicentem,n, J. Agostinho Marqueso,p
a Allergy Center, CUF Descobertas Hospital, Lisboa, Portugal
b Allergy Center, CUF Descobertas Hospital and CUF Infante Santo Hospital, Lisboa, Portugal
c CEDOC (Chronic Diseases Research Center), NOVA Medical School, Lisboa, Portugal
d Pulmonology Department, Centro Hospitalar de Lisboa Central, Lisboa, Portugal
e NOVA Medical School, Lisboa, Portugal
f Family Medicine, Porto, Portugal
g Coordinator of GRESP (Grupo de Estudos de Doenças Respiratórias da APMGF), Portugal
h Pulmonology Department, Centro Hospitalar Universitário de Coimbra, Portugal
i Faculty of Medicine, University of Coimbra, Portugal
j Family Medicine USF João Semana, Ovar, Aveiro, Portugal
k Coordinator of GRESP Inhalers and Technical Devices Working Group, Portugal
l Immunoallergology Department, Centro Hospitalar Universitário de Coimbra, Portugal
m Family Medicine UCSP Soure, Coimbra, Portugal
n Secretary of GRESP (Grupo de Estudos de Doenças Respiratórias da APMGF), Portugal
o Pulmonology Department, Centro Hospitalar de São João, Porto, Portugal
p Faculty of Medicine, University of Porto, Portugal
Ver más
This item has received

Under a Creative Commons license
Article information
Full Text
Bibliography
Download PDF
Statistics
Tables (2)
Table 1. Breath-actuated inhalers: key advantages and disadvantages.
Table 2. Key attributes of the breath-triggered k-haler®.
Show moreShow less
Full Text
Dear Editor,

Asthma affects the lives of several hundred million people around the World, across all age groups and Portugal is not an exception, with an asthma lifetime prevalence of 10.5%.1 Patients, their families and the society face high direct and indirect costs, due to healthcare resources use, loss of productivity, absenteeism and presenteeism of patients. Asthma strongly influences the wellbeing and quality of life of patients. With no established curative treatment, guidelines for asthma management have identified that the primary goal of management is to achieve asthma control.2 In asthma, pharmacological treatments mainly consist of inhaled drugs, which allow efficacy and significantly reduce systemic side effects, being the most efficacious treatments. However, lack of adherence to treatment in asthma occurs in more than half of all medical prescriptions. Furthermore, reduced adherence to treatment frequently allies with an incorrect inhalation technique, both considered major issues significantly impairing pharmacologic treatments effectiveness. Therefore, despite the efficacy of the available drugs, a high percentage of asthmatics are uncontrolled and have frequent exacerbations.

Difficulties in using inhalation methods are well-known problems that have been consistently maintained in recent decades, with the occurrence of several errors that affect treatment results with the use of both dry powder inhalers (DPIs) and pressurized metered-dose inhalers (pMDIs). Results from the Critikal study3 analyses of the inhaler technique assessment initiative Helping Asthma in Real-life Patients (iHARP) database have helped to identify the prevalence of critical inhaler errors (those that have a definite detrimental impact on the delivery of drug to the lungs) with different devices in patients with asthma. The most common critical errors included failure to coordinate device actuation and inhalation with pMDIs, and lack of a forceful inhalation with DPIs; overall, 89% of patients made at least one potentially critical handling error and 67% made multiple potentially critical errors.3

Breath-actuated inhalers (BAIs) represented an evolution in inhalers’ design aiming to improve the management of asthma.4 BAIs are aerosol devices, like pMDIs, but rather than being activated manually, they automatically release a dose of drug when the patient inhales with a sufficient inhalation flow rate. In the past, BAIs had a major limitation when chlorofluorocarbon propellants (CFCs) were used and the speed of emission of the aerosol was so high that the impact of inhaled droplets in the upper airways was still very significant; nowadays, with hydrofluoroalkane propellants (HFAs), the speed of emission is considerably lower and the aerosol may be inhaled slowly being deposited more peripherally in the airways. These new devices may offer several advantages (Table 1), and were developed to overcome the most commonly seen critical errors with other inhalers, as follows: there is no need to coordinate actuation and inhalation (which is necessary for pMDIs); as active devices, BAIs emit a propelled aerosol and patients do not need to inhale forcibly to generate respirable particles (which is required for DPIs).4,5

Table 1.

Breath-actuated inhalers: key advantages and disadvantages.

Advantages  Disadvantages 
Portable and compact• Multi-dose device• High reproducibility in the amount of drug delivered• Closed canister, so contents cannot be contaminatedBenefits over conventional pMDIs– No need to coordinate inhalation and actuationBenefits over DPIs– Releases drug at low inspiratory force, so no need to inhale forcibly  • Available for a limited range of drugs• Suspension formulations need to be shaken before each use• Important to prime before first use, if not used for some time or if the inhaler has been exposed to cold temperatures 

BAIs are intended to simplify the inhaler technique, leading to improved inhaler use by the patients and less health care professional (HCP) time spent training patients to use the devices correctly.4 Indeed, several studies have shown that patients find BAIs easier to use and HCP find it easier to train patients in their correct use in relation to other devices. The ease of use of BAIs may offer particular advantages in certain patient groups, such as children, the elderly or those with limited manual dexterity.4,5 BAIs that are triggered by a low inspiratory force may offer additional advantage.4

An ergonomically designed breath-triggered inhaler (BTI), k-haler®,5 was recently available. Its successful use involves only a few steps and, as an ‘active’ aerosol inhaler, it automatically releases a dose of the drug in a respirable form when a patient inhales, even at a low inspiratory flow (the device is triggered at an inspiratory flow rate of approximately 30L/min). A high fine particle fraction and a plume that is less forceful than that of previous pMDIs can decrease drug impaction at the back of the throat and improve delivery to the lungs.5 As such, k-haler® represents an added-value to improve asthma control by addressing current patients’ needs and overcoming the most common lasting critical errors referred with other inhalers (Table 2).5

Table 2.

Key attributes of the breath-triggered k-haler®.

General design
Minimal inhalation force is required to trigger the device  • Ensures that a dose is released even if the patient has limited lung capacity and gives a ‘nice feel’ upon actuation 
Shape  • Retains the classic ‘pMDI’ shape familiar to patients; the size and shape of DPIs vary considerably, which can lead to patient confusion 
Orange translucent cap and silver detailing  • Helps patients to orientate the inhaler correctly and to identify the mouthpiece correctly 
Small, compact size  • Easy to store and carry, and fits nicely in the hand (even small hands)• Can be used discreetly and has a comfortable fit in the mouth 
Closed system  • Prevents dirt and dust from accumulating in the inhaler that could clog the device and irritate patients’ airways 
Usability
Open–breathe–close operation  • Few simplified steps are required to prime and operate the device 
Cap is connected to the device  • The cap cannot be lost and can be repositioned easily when priming/closing 
Dose feedback
Easy-to-read dose counter in font designed specifically by the UK Royal National Institute for the Blind  • Ensures that patients know how many doses are left 
Audible ‘clicks’ when dosing and when closing  • Feedback that the device is primed and ready for use and also when the cap has been closed securely 
Automatic release of dose when the mouthpiece cap is closed if a primed dose is not taken  • Alerts the patient that a dose has not been taken• Prevents double or multiple-dosing 

The simplicity of use, better inhaler handling and patient preference for BAIs are advantages that may translate into improved treatment compliance with the prescribed therapy, leading to improved lung function and asthma control compared with other devices.4–6 Several controlled studies comparing the efficacy of drugs at equivalent nominal doses administered with different devices had demonstrated equivalence in the main clinical outcomes (mostly symptoms and exacerbations) of asthma (or chronic obstructive pulmonary disease), but this may be justified by, 1. the large number of variables affecting the clinical response to inhaled drugs, besides the inhalation technique and 2. the gap between the patients in clinical trial conditions in referral centers with specific characteristics and close monitoring, being aware that they are being evaluated, and those patients in the real world, where poor inhalation technique and low adherence to therapy are known to be more common.3–7

If correctly and effectively used, inhalers are excellent, safe and effective in controlling asthma, as in other chronic respiratory diseases.7 Improving inhalers correct and effective use is therefore a global issue to overcome current known difficulties and to move forward into achieving higher rates of asthma control.

Ethical disclosuresProtection of human and animal subjects

The authors declare that no experiments were performed on humans or animals for this article.

Confidentiality of data

The authors declare that no patient data appears in this article.

Right to privacy and informed consent

The authors declare that no patient data appears in this article.

Funding

None to declare.

Conflicts of interest

None to declare.

References
[1]
A. Sá-Sousa, M. Morais-Almeida, L.F. Azevedo, R. Carvalho, T. Jacinto, A. Todo-Bom, et al.
Prevalence of asthma in Portugal – The Portuguese National Asthma Survey.
Clin Transl Allergy, 2 (2012), pp. 15
[2]
Global Initiative for Asthma (GINA). GINA report, global strategy for asthma management and prevention. http://ginasthma.org/2019-gina-report-global-strategy-for-asthma-management-and-prevention [accessed 16.3.20].
[3]
D.B. Price, M. Román-Rodríguez, R.B. McQueen, S. Bosnic-Anticevich, V. Carter, K. Gruffydd-Jones, et al.
Inhaler errors in the CRITIKAL study: type, frequency, and association with asthma outcomes.
J Allergy Clin Immunol Pract, 5 (2017), pp. 1071-1081
[4]
S. Salvi, J. Gogtay, B. Aggarwal.
Use of breath-actuated inhalers in patients with asthma and COPD – an advance in inhalational therapy: a systematic review.
Expert Rev Respir Med, 8 (2014), pp. 89-99
[5]
O. Usmani, N. Roche, J. Marshall, H. Danagher, D. Price.
An innovative corticosteroid/long-acting β2-agonist breath-triggered inhaler: facilitating lung delivery of fluticasone propionate/formoterol fumarate for the treatment of asthma.
Expert Opin Drug Deliv, 16 (2019), pp. 1367-1380
[6]
D. Bell, L. Mansfield, M. Lomax.
A randomized, crossover trial evaluating patient handling, preference, and ease of use of the fluticasone propionate/formoterol breath-triggered inhaler.
J Aerosol Med Pulm Drug Deliv, 30 (2017), pp. 425-434
[7]
D. Price, J. Haughney, E. Sims, M. Ali, J. von Ziegenweidt, E.V. Hillyer, et al.
Effectiveness of inhaler types for real-world asthma management: retrospective observational study using the GPRD.
J Asthma Allergy, 4 (2011), pp. 37-47

These authors should be considered co-first authors (equal contributions and credit to the work).

Copyright © 2020. Sociedade Portuguesa de Pneumologia
Pulmonology
Article options
Tools

Are you a health professional able to prescribe or dispense drugs?